Oxima® 3 Light Weight Vital Signs Patient Monitor

$495.00$590.00 (-16%)

In stock

FREE SHIPPING! Delivery in 3 Days

Oxima® 3 Light Weight Vital Signs Patient Monitor

It can be applied in the hospital’s operation room ICU clinic section office
Out-patient department sickroom and emergency treatment.

Oxima® 3 Light Weight Vital Signs Patient Monitor Efficient performance patient monitor
Easy to use
Four parameters: NIBP. SpO2. Pulse Rate. TEMP
Suitable for adult pediatric and neonatal
Battery capacity indicator and prompt when battery low
Large screen : SpO2 PR are shown on LED screen Pleth waveform is displayed on 2.8″ color screen in real time
24 hours or AC power and Built-in rechargeable Li-ion battery up to 6 hour running time
Storage/Review trend data up to 3888 groups data save time interval settable
Automatic shutdown for power saving shutdown time interval settable
Audio and visual alarm when parameters exceeded and sensor-off

Options
Thermal Printer

Oxima® 3 Vital signs monitor three parameters: NIBP,SpO2 and TEMP

NIBP:
Measurement method: Oscillometric
Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg
Measurement unite: MmHg/kPa selectable
Measurement mode: Manual Auto STAT
Measurement Type: SYS DIA MAP
Measurement interval in AUTO mode: 1 2 3 5 10 15 20 30 45 60Min
Measuring period in STAT mode: 5 Min
Resolution: 1mmHg
Over-pressure protection: Adult: 300mmHg Pediatric: 220mmHg

SpO2:
Range: 0 -100%
Resolution: 1 %
Accuracy: 2% (90~99%) 3% (70~89%) unspecified (< 70%)

PR:
Range: 30bpm~250bpm
Resolution: 1bpm
Accuracy: 2bpm

TEMPERATURE
Channel 2
Measuring and Alarm Range 0 ~ 50 °C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.

IBP (optional)
Channel 2
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0~300mmHg
PA -6~120mmHg
CVP/RAP/LAP/ICP -10~40mmHg
P1~P2 -10~300mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1mmHg
Accuracy ±2% or 1mmHg which great
Actualization Interval about 1 Sec

Power Requirements:
AC power adaptor
Input: AC 100~240V 50/60Hz 0.7A
Output: 5V 2.5A
Internal battery
Type: 2.8A build-in Li-ion rechargeable battery
Operating Time: 6 hours of stand-by time with a full battery.
Recharge time: 8 hours

Oevice dimension: 210mm × 188mm × 107mm
Net Weight: 1000g

Standard:

SpO2 Cable (Adult) …….. 1Pcs
NIBP Cuff (Adult) ………… 1Pcs
NIBP Tube(150cm) ……… 1Pcs
Temp sensor…………………..1pcs
Power Adapter ……………… 1Pcs
Cleaning Cloth ……………… 1Pcs

Options:

Cable Sp02 (Adult
Soft Sensor the shell) Sp02 Cable ( Adult Soft Sensor the shell)
Sp02 Cable (Neonatal Soft Sensor)
SpO2 Cable (Pediatric hard shell sensor)
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Child finger clip)
SpO2 Cable (multi-site Y type)
SpO2 External Cable
NIBP Cuff (infant 8 – 14 cm 5/Bag)
NIBP Cuff (Child 13 – 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
NIBP Cuff (Adult 26 – 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
NIBP Cuff (Thigh 42 – 50 cm)
NIBP Tube 150cm
Paper Role
Thermal printer

Average Rating

4.00

01
( 1 Review )
5 Star
0%
4 Star
100%
3 Star
0%
2 Star
0%
1 Star
0%
Add a review

Your email address will not be published. Required fields are marked *