Spirometer Pro

$1,350.00$1,850.00 (-27%)

In stock

FREE SHIPPING! Delivery in 3 Days

The portable pulmonary function measurement instrument can be used to measure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilator Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)

Download Catalogue

Categories: , Tag:

Measuring principle
When be normally breathing, the gas passed through the flow sensor. On both sides of the screen of the sensor will produce different pressure. The pressure is detected by the sensor, which is converted to electrical signals. After the signal amplification, AD converter sampling, the pressure is converted to digital signal into the computer system.
Through digital signal processing and analyzing technology, computer system reproduces the breathing waves that are displayed on the LCD together with analyzed results. In the end the built-in printer prints out the analysis results.Single use filter

Single use mouth set
Nose clip
The portable pulmonary function measurement instrument can be used to measure:
                    Vital capacity (VC)
                    Forced vital capacity (FVC)
Maximum Ventilator Volume (MVV).

Measurement algorithm refers to the ITS ERS standards of the American Thoracic Society (ATS)

Measurement of breathing time:
                   VC time 50 seconds
                   FVC measuring time 25 seconds
                   MVV time 12 seconds in favor of the coordination between patients and the device
Adopting pressure-flow sensor sensitive precise easy to launder clean and durable
All parameters can be displayed on large screen(320 x 240)
Built-in memory can store maximum 300 cases of patient measurement results
The instrument can calibrate automatically all English operation more convenient to operate
110mm thermal printer built-in can print out a clear clinical report predicted value measured value

Compact and flexible

SpioSoft PC Software for data transfer (Options)

Measurement methods:
Flow velocity detection:  Screen type pneumotachograph flow sensor
Capacity detection:      flow integration

Patient Data:

  Patient   information
input
Patient ID ID No.: XXXXXX ID No.: XXXXXX
Gender Gender: Gender:
Age Age: Age: Years old
Height Height: Height: cm
Weight Weight: Weight: kg
Race Race: Race:
Temperature Temperature: Temperature:
Humidity Humidity: Humidity: %
Atmosphere Atmosphere: Atmosphere: mmHg

Measuring range
Capacity range:         0L ~ 9L
F low velocity range: 0 ~ 14L / s

Measurement accuracy
Capacity:                     0L ~ 1.6L (± 50ml)
6L ~ 9L (± 3%)
Flow rate:                    5% or 0.2L / s
Respiratory rate:          4 / 20 ~ / min (± 1 / min)
20 / 60 / min (error: ± 5%)

Measuring time limit and degree
VC:                        50s per time, measuring 3 times
FVC:                      25s per time, measuring 3 times
MVV:                     12 seconds per time, measuring 3 times

PARAMETER DESCRIPTION DISPLAY PRINT UNIT
VC Test Vital capacity,Maximum inspiration volume or Maximum exhalation volume VC VC L
Tidal volume TV TV L
Expiratory reserved volume ERV ERV L
Inspiratory reserved volume IRV IRV L
Inspiratory capacity IC IC L
FVC Test Forced vital capacity FVC FVC L
Forced expiratory volume at 0.5sec FEV0.5 FEV0.5 L
Forced expiratory volume at 1sec FEV1.0 FEV1.0 L
Forced expiratory volume at 3sec FEV3.0 FEV3.0 L
Forced expiratory volume1sec / Forced vital capacity FEV1.0/G FEV1.0/G %
Forced expiratory volume1sec / vital capacity FEV1.0%T FEV1.0%T %
Forced expiratory volume at 3sec / Forced vital capacity FEV3.0%G FEV3.0%G %
Forced expiratory volume at 3sec / vital capacity FEV3.0%T FEV3.0%T %
Extrapolated volume Vext Vext L
Expiratory time EX Time EX Time s
Maximal mid-expiratory flow MMF MMF L/s
Peak expiratory flow PEF PEF L/s
Mid(forced)-expiratory flow at 75% MEF75 MEF75 L/s
Mid(forced)-expiratory flow at 50% MEF50 MEF50 L/s
Mid(forced)-expiratory flow at 25% MEF25 MEF25 L/s
Forced inspiratory vital capacity FIVC FIVC L
Forced inspiratory volume at 0.5sec FIV0.5 FIV0.5 L
Forced inspiratory volume at 1.0sec FIV1.0 FIV1.0 L
Ratio of FIV1.0divided by FIVC FIV1.0/FVC FIV1.0/FVC %
Ratio of FIV1.0divided by FVC FIV1.0/FIVC FIV1.0/FIVC %
Peak inspiratory flow PIF PIF L/s
Inspiratory flow at 50% MIF50% MIF50% L/s
MVV Test Maximum voluntary ventilation MVV MVV L/min
Respiration rate RR RR /min
Tidal volume TV TV L

Display (LCD): 320 * 240 dot-matrix
printer: 110mm thermal printer
Data: 10 integral records

Other Note

Power: A.C. 100~220V 50/60Hz
The type of security: I Class B type

Transport and storage note
Ambient temperature range:-20°C ~ 55°C;
Relative humidity range: ≤ 93%;
Atmosphere pressure range: 500hPa ~ 1060hPa;

Working note
Surrounding temperature range: 10°C ~ +40°C;
Relative humidity range: 30% to 75%;
Atmosphere pressure range: 700hPa ~ 1060hPa;

Options:
SpioSoft PC Software for data transfer (Options)

Standard:

Antibacterial – Viral Filter  …… 1Pcs

Single use mouth set   ……….. 1Pcs
Nose clip   ………………………… 1Pcs
Ground Wire    ………………….. 1Pcs
Power cable  …………………….. 1Pcs
Cleaning Cloth  …………………. 1PcsOptions:USB Cable   ……………………… 1Pcs

Be the first to review “Spirometer Pro”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Main Menu