MD09X Wrist Multi-Parameters and Individual Parameter Patient Monitor

FREE SHIPPING! Delivery in 3 Days

MD09X wrist multi-parameters and individual parameter patient monitor.
The smart multi-parameters patient monitor with a small size can simultaneously measure the ECG, Heart rate, Respiration, Blood pressure, SpO2 and Pulse rate.
It can respectively measure the Blood pressure, SpO2 or the both.

Original price was: $795.00.Current price is: $595.00.

(1 customer review)

Guaranteed Safe Checkout

Features & Compatibility

2.4 inch TFT color screen . Resolution: 320*240
Display waveform: 2 channels waveform of ECG, respiration, blood pressure and SpO2 can be both displayed
ECG: With the function of abnormal data store, daily data store and trend display
ECG Cable: 3 leads .10 Leads
NIBP: Manual measurement. Automatically identify the adult and child. System can adjust the maximal pressure for adult and child. The blood pressure waveform can be displayed in real-time
SpO2: Anti-low per-fusion and motion artifact
Trend display: Display the trend of ECG, blood pressure, SpO2, ST segments, premature and respiration in 96 hours
Alarm modes: Visible alarming reminder and speaking voice alarming reminder
Wireless: Bluetooth 4.0
E-Manual: Embedded e-manual for self reading
workable with smart devices (Android &iOS)

ECG
ECG waveform gain: 0.5 mm / mV,1.0 mm / mV, 2.0 mm / mV
Scanning speed : 7.5mm / s, 15mm / s
Heart rate and alarm range :
Adult: 30 bpm ļ½ž250 bpm (beats / min)
Precision of ECG: ±5%
Resolution: 1 bpm (Times/Minute)
Sensitivity: ļ¼ž200uV (Peak-to-Peak Value)
Trigger level threshold: 200nV (Lead II)
Resistance of differential input: ļ¼ž5MĪ©
Common-mode rejection ratio : ≄ 90 dB
Electrode polarization voltage range: 300mV
Leakage current: <10uA
Input signal range: ±5mV
ECG abnormal types:Tachycardia, Bradycardia, VPC, Bigeminal rhythm, Trigeminal rhythm, RonT, VTAC, Escape Beat and Sinus arrest.
Alarm:The voice audible alarm and screen visual alarm display dual alarm, under review.
Heart rate alarm range: 30ļ½ž250 bpm
Alarm Mute: Less than 10 seconds
Alarm sound pressure: 45 to 65 db
Frequency response :
Flter : 0.67 Hz ļ½ž 40Hz
Guardianship : 0.05 Hzļ½ž40Hz
Detection: 0.05 Hzļ½ž100Hz
Calibration signal : 6 mm / mV
ST segment measurement:
Measured range: -2.0mVļ½ž+2.0mV
Precise: -0.8mVļ½ž+0.8mV; ±0.02mV or±10%
Renew period: 10s
Pacing pulse suppression :
Range: ± 2mV to 500Mv
Width: 0.1ms ļ½ž 2ms
Rise time: 10us ļ½ž 100 μs
Inhibition of the pacing pulse detector for fast ECG signal : 2.5V/s
Can inhibit the T-wave amplitude: > 5mV

Noninvasive blood pressure (NIBP)
Measurement: Oscillometric pressure when the blood pressure measurement.
Pressurized automatic calibration zero
Measuring range : 30mmHgļ½ž280mmHg
Measurement accuracy : ±5mmHgor ±5%
Maximum cuff pressure: Cuff pressure does not exceed 300 mmHg,
The cuff pressure at 15 mmHg or more time is not more than 3min.
Overvoltage protection: Yes
Alarm: Systolic / diastolic alarm error of ± 2 mmHg
Atrial premature function
Measuring wrist Week 135mm ļ½ž 215mm

Oxygen saturation (SpO2)
Measuring range : 40% ļ½ž 99%
Measurement accuracy: 90% ļ½ž 99% Tolerance ± 2%
70% ļ½ž 89% Tolerance ± 4%
40% ļ½ž 69% Tolerance ± 6%
Alarm range : 50% ļ½ž 99%

Pulse rate
Measuring range : 30 Beats / min ļ½ž 80 Beats / min ± 2
80 Beats / min ļ½ž150 Beats / min ± 4
150 Beats / min ļ½ž240 Beats / min ,± 5
Measurement accuracy: ± 5%

Resist electric shock : CF type
Build-in : 3.7V 1000mh
Power adapter: 5V/1A 2W battery charger:
Power 2W
Type : Non-AP / APG type Do not prevent inlet device
Work environment:
Temperature: 5 ā„ƒļ½ž40 ā„ƒ
Humidity: 15% ļ½ž80%
Atmospheric pressure: 80kPa ļ½ž105kPa
Storage environment:
Temperature : -20 ā„ƒ ļ½ž55ā„ƒ
Humidity : 10%ļ½ž90%
Atmospheric pressure : 50.0 kPa ļ½ž106.0kPa

Size and Weight
Dimensions : 7cm (W) Ɨ 7cm (H) Ɨ2.6cm (D) (does not include a wrist strap)
Net Weight : 130g
Gross Weight 0.5Kg

Standard:

ECG Cable (3 Leads) …… 1Pcs
SpO2 probe (Soft tip) ….. 1Pcs
Power Adapter ………….. 1Pcs
Cleaning Cloth ……………. 1Pcs

Options:

ECG Cable (10 Leads)

Additional information

Customer Reviews

1 review for MD09X Wrist Multi-Parameters and Individual Parameter Patient Monitor

  1. Maria Colmenares

    This system has all the features for elderly patients and sick younger patients whether they are at home or hospital or convalescent home It will be on my list of high ones to acquire and I will continue my review to pick the right one

Add a review

Your email address will not be published. Required fields are marked *